The Wireless Key can be used in conjunction with the PC5132 Wireless Receiver to include a simple and mobile method of arming and disarming the system. It is a disposable transmitter in that it is Ultrasonically welded together and the battery is not user changeable. The wireless Panic Pendant can be used in conjunction with the PC5132 Wireless Receiver to include personal wireless protection. The unit comes with three ‘AAA’ batteries and has built-in contacts. The wireless Slimline Universal Transmitter can be used with the PC5132 Wireless Receiver to add wireless door or window contacts in a smaller package. WLS907 Wireless Slimline Universal Transmitter The wireless Smoke Detector can be used in conjunction with the PC5132 Wireless Receiver to include wireless smoke detection. The unit comes with four ‘AAA’ batteries. The wireless Motion Detector can be used in conjunction with the PC5132 Wireless Receiver to include wireless space protection. (See PC5132 Installation Manual.)Īdditional wireless devices are available: All devices are spread spectrum, 900 MHz, fully supervised and use standard ‘AAA’ or ‘AA’ alkaline batteries (See Section 5.27 “Wireless Expansion”). The PC5132 Wireless Receiver module can be used to connect up to 32 wireless devices. (See PC5108 Installation Instructions Sheet.) 1.2.3 PC5132 Wireless Receiver Module Up to 3 modules can be connected to increase the system zones to a maximum of 32. Different keypads (with function keys) can be used for different size systems 8 zone, 16 zone and 32 zone.Įight zone expander module can be used to increase the number of zones on the system.

  • Upload/Download Capability 1.2 Additional Devices 1.2.1 KeypadsĪ maximum of eight (8) keypads can be connected to the control panel and can be any combination of the following listed.
  • 128 Event Buffer, Time and Date Stamped.
  • Supports the Escort5580 Voice Prompt Module with Automation/Lighting Control.
  • Dsc alarm panel installation manual serial#

  • Event Buffer can be printed using PC5400 RS232 Serial Interface module.
  • All modules connect to the system via a four wire Keybus up to 1000’/305m from main panel.
  • Audio Capability using the PC5928 Audio Interface Module which allows local intercom and Central Station 2-Way Listen in.
  • Keypad Activated Alarm Output and Communicator Test.
  • Auto Arm by Partition at Specified Time.
  • The PC5010 continuously monitors a number of possible trouble conditions including:
  • Split Reporting of Selected Transmissions to Each Telephone Number.
  • Supports LINKS1000 Cellular Communication.
  • Supports all Major Formats including SIA and Contact ID.
  • Each Keypad has 5 Fully Programmable Function Keys.
  • LCD5500(Z)/KPL5500 (Z) Alphanumeric Keypad
  • Battery = 12 volt 4 Ah minimum rechargeable sealed lead acid.
  • dsc alarm panel installation manual

  • Internal Clock Locked to AC Power Frequency.
  • Supervision for loss of AC Power, Low Battery.
  • Positive Temperature Coefficient (PTC) components replace fuses.
  • 1 PC5204 Output Fully Supervised for Siren Output.
  • Four High Current (1 Amp) PGM outputs Available Using the PC5204 module.
  • Eight Additional Low Current (50 mA) PGM outputs available using the PC5208 module.
  • One Low Current (50 mA) PGM output on main panel.
  • Maximum Loop Current is 1.5 mA when the 2-wire smoke detector configuration is used.
  • One High Current (300 mA) PGM output with 2 wire smoke detector capability on main panel.
  • Up to 14 Programmable Voltage Outputs, 23 programmable options.
  • Will not lose programming or system status on complete AC and Battery failure.
  • Supervised Bell Output (current limited at 3 amps), 12 V DC.
  • 27 Zone Types, 8 Programmable Zone Options.
  • Normally Closed, Single EOL, or Double EOL zone supervision.
  • Wireless expansion available using the PC5132 Wireless Zone Expansion Module (up to 32 wireless zones, 900MHz, True Spread Spectrum Technology, Fully Supervised).
  • Hardwired expansion available using the PC5108 Eight Zone Expansion Module.
  • Keypads with zone inputs available (PC/KP5508Z, PC/KP5516Z, PC/KP5532Z, LCD/KPL5500Z).
  • 38 Access Codes: 32 User, 1 System Master, 2 Partition Master, 2 Duress and 1 maintenance.
  • 5.31.2 Factory Default Main Panel (Software) and other Modules.
  • 5.31.1 Factory Default Main Panel (Hardware).
  • 5.26.3 Using the LINKS as a Redundant Communicator.
  • 5.26.2 Using the LINKS as a Backup Communicator.
  • 5.26.1 Using LINKS1000 as the Sole Communicator.
  • 5.16.1 Viewing the Event Buffer through the LCD Keypad.
  • 3.7 Features Available for the LCD5500Z.
  • 3.6 Global and Partition Keypad Operation.
  • 2.9.7 LINKS Supervisory (24 Hour Supervisory).
  • 2.9.5 Fire Zone Wiring - 2 wire Smoke Detectors.
  • 2.9.4 Fire Zone Wiring - 4 wire Smoke Detectors.
  • 2.9.3 Double End of Line (DEOL) Resistors.
  • 2.4 Current Ratings - Modules and Accessories.
  • 1.2.6 PC5208 Eight Low Current Output Module.
  • 1.2.5 PC5204 Power Supply Output Module.
  • 1.2.4 PC5100 Addressable Service Interface Module.
  • 1.2.2 PC5108 Eight Zone Expander Module.